Leaders in Oil-Filled and Ceramic High Voltage Capacitor Technology
A |
||
TYPE |
L |
D |
HT 53 |
0.484 |
0.562 |
B |
||
TYPE |
L |
D |
HT 53 |
0.437 |
0.500 |
HT53 Series 5 KVDC
Body |
Cap |
Maximum Current Rating |
||||||||
TC |
(pF) |
Part No. |
1 MHZ |
10 MHZ |
30 MHZ |
|||||
NPO |
7 |
HT53T709DA |
.16* |
1.54* |
3.8 |
|||||
10 |
HT53T100KA |
.22* |
2.20* |
4.0 |
||||||
15 |
HT53T150KA |
.33* |
2.8 |
4.1 |
||||||
20 |
HT53T200KA |
.44* |
2.9 |
4.5 |
||||||
25 |
HT53T450KA |
.55* |
3.0 |
4.8 |
||||||
N-750 |
30 |
HT53T300KA |
.66* |
3.1 |
5.0 |
|||||
35 |
HT53T350KA |
.77* |
3.6 |
5.1 |
||||||
40 |
HT53T400KA |
.89* |
3.7 |
5.2 |
||||||
45 |
HT53T450KA |
1.00* |
3.8 |
5.3 |
||||||
*Data is based on not exceeding the maximum rated
voltage. All other data is based on a 30°C rise above a 25°C ambient in still air.
NOTES:
1. Reactive power ratings (KVAR) can be calculated
from given currents. Within given frequency limits the following equation applies:
![]()
2. Capacitor data is based on actual tests of current necessary to obtain a 30°C rise. In
operation, capacitors may be driven to a 50°C rise over a 25°C ambient and still have a
10°C service factor.
3. Final suffix "A" designates terminal cap. For wire termination, change suffix
to "B".
4. Capacitance tolerance is ±.5 pF with letter "D" as second from end in part
number, or is ±10% pF with letter "K" as second from end in part number. For
tighter tolerance part change "D" to "C" for ±.25 pF and change
"K" to "J" for ±5% pF.
PO Box 308 / Lower Valley Road
Parkesburg, PA 19365
610-593-2800 FAX 610-593-2985